Stair calculator
Enter the floor-to-floor rise to estimate a straight flight. The upper landing counts as the final walking surface.
Your stair geometry
Enter the total floor-to-floor rise, check the visible defaults, then calculate.
Results include riser and tread counts, actual rise, horizontal run and a proportional side view.
Application bounds: total rise above 0–240 in; maximum riser 0.25–24 in; tread depth above 0–60 in; up to 128 risers. These are tool limits.
Headroom, landing design, handrails, nosings, construction tolerances, loads, end cuts, local adoption and amendments are not evaluated. No structural plan, cut list or concrete-volume estimate is provided.
Reference: ICC-hosted 2021 IRC Plan Review training PDF, pp. 24–25, accessed October 11, 2026. The direct code-section page was inaccessible; this reference does not verify locally adopted code.
WORKED EXAMPLE
How the stair count is worked out: a 108 in rise
One straight flight, measured finished floor to finished floor, with the default 7.75 in maximum riser and 10 in treads.
- Total rise
- 108 in
- Maximum riser
- 7.75 in
- 108 ÷ 7.75 = 13.94, rounded up
- 14 risers
- Actual riser 108 ÷ 14
- 7.714 in
- Constructed treads 14 − 1
- 13
- Total run 13 × 10 in
- 130 in
The upper landing is the last walking surface, so there is one fewer tread than risers. Dimensional reference: 2021 IRC plan-review material, reviewed October 11, 2026; local amendments are not verified.
COMPARE
Lower maximum riser vs the default
Same 108 in rise and 10 in treads. A lower riser limit makes the steps easier to climb but adds treads and floor length.
Maximum 7.5 in
157.2 in140 inMaximum 7 in
166.75 in150 inEach extra riser adds one tread, so the run grows by one tread depth. Check the run against the space you have before choosing a limit.
CHECKLIST
Common stair measuring mistakes
Checks before you cut anything.
Measuring subfloor to subfloor
Flooring added later makes the top or bottom riser differ from the rest. Measure finished heights or add the planned flooring first.
Measuring on a slope
Use a level and measure straight down where the flight will land, not at the edge of a sagging floor.
Laying out the maximum
The maximum riser is a limit. Lay out every riser at the actual height, 7.714 in in the example, not 7.75 in.
Too much rise for one flight
The reference limits one flight to 151 in of rise. Taller rises usually need a landing that splits the flight in two.
Using the diagonal as a stringer
The slope estimate ignores end cuts, nosings and support. A stringer needs its own layout.
Forgetting what is not checked
Headroom, landings, rails and loads are outside this tool. Ask your local building authority before you build.
HOW IT WORKS
How the stair calculator works
Enter the total rise of one straight flight. The calculator divides it into equal risers no taller than your maximum, counts the treads, and multiplies by the tread depth to find the floor space the flight needs.
Measure the total rise
Measure from finished floor to finished floor with a level, at the spot where the flight will land.
Set the riser and tread limits
The defaults are a 7.75 in maximum riser and a 10 in tread. Change them if your plan or local rules differ.
Read risers, treads and run
Lay out every riser at the actual height shown. The run is the floor length from the first riser to the last.
FORMULA
risers = ceil(total rise ÷ maximum riser) actual riser = total rise ÷ risers treads = risers − 1; run = treads × tread depth
Example: 108 in → ceil(108 ÷ 7.75) = 14 risers of 7.714 in, 13 treads, 13 × 10 = 130 in of run
Geometry for one straight flight only. Headroom, landings, rails and structure are not checked; ask your local building authority about the rules that apply.
Common questions
How does the calculator count risers and treads?
It divides the total rise by the maximum riser and rounds the count up. The actual riser height is the total rise divided by that whole count. A flight with N risers has N − 1 constructed treads because the upper landing is the last walking surface, and the horizontal run is constructed treads × tread depth.
Which dimensional limits does it check?
It checks the 2021 IRC dimensional reference: actual riser 7.75 in or less, tread depth at least 10 in when a tread exists, and single-flight rise 151 in or less. The source is ICC-hosted plan-review training material, pages 24–25, reviewed October 11, 2026. Local adoption and amendments are not verified.
What does the calculator not check?
Headroom, landings, rails, nosings, loads, structural design and cut details are outside this tool, and the dimensions you enter are not verified. Ask your local building authority about the rules that apply where you build.
Why is the maximum riser different from the result?
The maximum sets an upper limit. Rounding the riser count up usually makes each actual riser a little shorter.
Why one fewer tread than risers?
The count treats the upper landing as the final walking surface. One riser therefore has zero constructed treads and zero horizontal run.
Does switching units change the flight?
The tool retains exact dimensions while displaying inches or centimeters. Editing a displayed value replaces that dimension.
Can I use the diagonal as a stringer cut length?
No. End cuts, support, nosings and construction details need a separate design. Concrete volume and structural stringer calculations are outside this tool.
What if my total rise is more than 151 inches?
The tool flags a single-flight rise over 151 in against the IRC dimensional reference. A taller rise usually needs an intermediate landing, which splits it into two flights. Plan that with your local building authority; this calculator handles one straight flight only.