Attic insulation calculator

Find the R-value for your climate zone and how many bags of blown-in insulation to buy, using the product's own coverage chart.

Not sure? Check the ENERGY STAR zone map.

Insulation already in the attic
Attic size

or

Measure the floor of the attic, not the roof.

Product

Pick a climate zone to see the ENERGY STAR recommendation.

Your entries stay in this page. Nothing is saved, sent, or added to the address.

Your bag count shows up here

Pick your zone, attic size and product, then tap Estimate bags.

How the bag estimate works

Every brand's bag covers a different area at the same R-value. Calculators that don't tell you which product they assume can be off by several bags. We show the product, the R-value and the chart we used, plus the second number when the chart's own figures round differently.

Worked example: an uninsulated zone 5 attic

Choose climate zone 5, None for existing insulation, and Owens Corning AttiCat 27.5 lb bags. Enter 40 ft by 25 ft, which is 1,000 sq ft. Keep the recommended R-60 target.

At R-60, the AttiCat card lists 31.8 sq ft maximum coverage per bag. The calculator divides 1,000 by 31.8 and rounds up to 32 bags. The second chart figure, 31.5 bags per 1,000 sq ft, also rounds up to 32 for this area. Install at least 20.5 inches, as the result states.

The comparison for the same area and R-value is 28 bags of PROPINK L77 at a minimum 20.0 inches. Those are 32 lb bags with a different chart. A smaller bag count alone does not tell you which product costs less.

How to read the result

The climate-zone recommendation comes from the ENERGY STAR table for adding attic insulation to existing wood-framed buildings. Zone 5 shows R-60 for an uninsulated attic and R-49 to add when you already have about 3 to 4 inches. Check the linked map for your zone. Changing the existing-insulation option updates the suggested R-value; you can also change the target yourself.

Buy is the whole-bag count from the selected product coverage row. Minimum thickness is a separate requirement: spreading those bags too thin will not meet the chart. When the chart columns round to different counts, an extra line shows the bags-per-1,000-sq-ft check and the larger count as a spare suggestion. This is a material estimate, not a contractor quote.

Common mistakes

Measure the attic area you plan to insulate, not the sloping roof surface. If you enter both length and width, their product takes priority over the total-area field.

Check the bag weight and product name before shopping. The AttiCat and PROPINK L77 bag counts cannot be exchanged between products.

Do not treat R-60 as 60 inches of insulation. R-value describes thermal resistance; use the thickness printed for your selected product and target.

Do not assume a missing coverage row means zero bags. For example, zone 1 with existing insulation recommends R-25, which these stored product rows do not cover. The tool shows a coming-soon message instead of inventing a count.

When to use it

Use this to make a bag-and-thickness shopping list once you know your attic area, climate zone and existing insulation condition. Compare the two supported fiberglass products at the same target before checking local prices. For labor, equipment, attic repairs or a full installed price, get a separate quote and follow the product instructions.

Sources

Climate zones follow the ENERGY STAR zone map. We link that map rather than copying it.

Reviewed November 10, 2026

Common questions

Why does the insulation product change how many bags I need?

Each product has its own coverage chart. The calculator uses the selected product and R-value rather than assuming every bag covers the same area.

Can I enter attic dimensions instead of square footage?

Yes. Enter length and width in feet, or enter the total attic area in square feet.

Where can I find my climate zone?

Use the ENERGY STAR zone map linked in the Sources section, then select your zone in the calculator.

What R-value does zone 5 start with?

The ENERGY STAR table used here recommends adding R-60 to an uninsulated zone 5 attic, or R-49 when it already has about 3 to 4 inches of insulation. Select the existing condition that matches your attic and check the source guidance before choosing your target.

Why can the result show two different bag counts?

The coverage card prints both maximum square feet per bag and minimum bags per 1,000 square feet. Rounded chart figures can produce different whole-bag totals. The headline uses area divided by maximum coverage, rounded up; an extra check line appears if the other column gives a different count.

Can I use the bag count without measuring the installed depth?

No. The manufacturer requires both the specified bag count and at least the minimum installed thickness for that R-value. Check both against the label and installation instructions for the exact product you buy.

Does this estimate include installation costs or every insulation product?

No. It estimates bags and minimum thickness for the supported AttiCat and PROPINK L77 coverage rows. It does not price labor or materials. Cellulose and missing R-value rows show coming soon instead of an estimated bag count.

Estimates only, based on manufacturers' published coverage charts. This calculator does not provide professional, engineering or building code advice. Actual coverage and R-value depend on the product, installation and attic conditions. Before buying or installing, read and follow the product label, manufacturer instructions and local building code requirements. Use the protective equipment specified by the manufacturer.Do not disturb vermiculite insulation; it may contain asbestos. Keep attic vents clear and maintain required clearances around heat sources and recessed lights.

Privacy choices

Google messaging can contact Google before you choose. Ads stay off until advertising consent is verified. Google Analytics needs your consent in the EEA, UK and Switzerland, or when your country cannot be determined, and runs by default elsewhere unless you reject it or send Global Privacy Control.

Changing privacy choices can reload this page and clear unsaved entries. Copy or download any work you want to keep first.